SP Windlass Control Unit v1.0.0 2015
Troubleshooting
If the windlass still does not work normally after you have tried these procedures, the fault is in the windlass itself. Contact
your nearest dealer.
EN
FAULT SYMPTOM FAULT CODES/STATUS SOLUTION
Windlass does not operate "Power"LEDnotlit Check:
Mainswitch/breakerisengaged.
Checkbatteryfuses.
Visuallyinspectcablesandverifythatterminalsaretight.
Measurebatteryvoltage.
"Power"LEDlit Turnonpanel/remotecontrol(seeusermanual)
Seebelow:
Windlass only runs for 0,5 seconds
when pressing "IN"
None Checkcontrolpanelconnections.Signalsfor"IN"and"OUT"mightbe
swapped.
When pressing "OUT" free fall is not
engaged.
Or: When pressing "IN", motor is
running but gypsy is not turning
None SwapmotorcablesD1andD2onthecontrolunit
Windlass has poor performance “Lowvoltage” Voltagehasdroppedbelow9V
Checkbatteries.
None Measurebatteryvoltagewhileoperatingthewindlass.Ivoltagemeasure
below11V/22V,allowbatteriestocharge.
Ifthebatteryvoltageisacceptable,measurevoltageonthemotortermi-
nals,cablevoltagedropshouldbelessthan1Vwhenmotorisrunning.
Windlass releases anchor, but do
not wind in
None Checkthatendstopsensorisnotactive(Indicatedby"EndStop"LEDon
controlunitorLEDbuiltintothesensor.)
Checksensorconnectionsonthecontrolunit.
SensorLEDshouldnotbelitifnometalobjectispresentinfrontofit.
Windlass wind past endstop None Checkthattheendstopwirewoundaroundtheropeisintact.Pulltherope
withendstopwireovertheendstopsensorandverifythat(«EndStop»LED
lightup)
Adjustsensorclosertotheropeifneccesary.
Windlass releases anchor, but stops
immediatly when pressing "IN"
Noneor“Lowvoltage” Ifthebatteryisinpoorconditionitmightmeasure12/24Vwhenwindlass
isnotinuseandstillexperinceasignicantvoltagedropwhenthemotor
starts(suchvoltagedipsmightbediffculttomeasure)Thistypeofvoltage
dropscanleadtofalsetriggeringoftheendstopsensor.
Windlass stops during operation “MotorOverload” Currentlimitationhastriggered.
Thismeansthatthewindlassisoverloaded.Tryagainwithreducedload.
Ifthisfaultistriggeredwhilethewindlassislightlyloaded,itmightindicate
amechanicalfailure.
“ControllerOvertemp” Thecontrolunittemperaturesensoristoowarm.
Letthecontrollercooldown,andtryagain.
“MotorOvertemp” Themotoristoohot.
Thewindlasscontrollercalculatesmotortemperaturedependingonload
anruntime.
Letthewindlasscooldown.
“ControllerOverload” Thisfaultindicatesthattheinternalprotectionofthecontrrollerhastrig-
gered.Thiscanbecausedbyexccessivesurroundingtemperatureandhigh
load
“RuntimeExceeded” Signal"OUT"or"IN"havebeencontinuousformorethan5minutes.Thisis
aprotectionagainstpossiblefaultycontrolsignals.Re-activationispossible.
Abnormal noise during operation Thewindlassmustbeserviced.
Windlass operates, but rope is not
wound in
Theropecanslipinthegypsyifthewindlassismountedincorrectly.
Anchor is not released Theanchormightnotreleasefromthebracketifmountedincorrectly.
Note! Main switch/braker must be disconnected whenever working on the windlass mechanical parts